HEXECO, Inc.'s Hexchanger service is available for repair and refurbishment of heat exchangers. Some examples are shown below.

Retube and reconditioning of
a set of generator
hydrogen coolers for a municipal power
plant.

Refurbish feedwater heater assembly -
National Board Code Alteration with
inclusion of new ASME Code parts (channel & u-tube bundle
assembly). Re-used existing channel skirt and shell.

Retube of a
transformer oil cooler on a 1912 transformer. The
original cooler froze and was beyond repair. Existing supports
were re-conditioned and re-used.

Retube of split bundle
shell & tube design with individually
packed tubes. Original lead packing replaced with updated packing
material substantially increasing service life. Unit in municipal
power house on steam turbine.

Steam
heated air preheater for paper mill. Retubed
with extruded aluminum fins over 90/10 Cu/Ni tube, replacing
failed copper tube with tension-wrapped aluminum fins.

Two
types of steam coils for preheating paper
mill plant air. Retubed with extruded aluminum fins over 90/10
Cu/Ni tube, replacing failed copper tube with tension-wrapped
aluminum fins.
Other Links:
HEXECO, Inc. Bearing Oil Coolers
Copyright 1998 - 2008 HEXECO, Inc. ... a Heat Exchanger Engineering Company